status relay in safe area:
Max. voltage .............................................................. 125 VAC / 110 VDC
Max. current ............................................................... 0.5 AAC / 0.3 ADC
Max. AC power .......................................................... 62.5 VA / 32 W
approvals:
EMC 2004/108/EC .................................................. EN 61326-1
LVD 2006/95/EC ...................................................... EN 61010-1
c UL us, Standard for Safety ................................ UL 61010-1
GOST R
marine:
Det Norske Veritas, Ships & Offshore ............. Stand. f. Certific. No. 2.4
i.s. / Ex:
ATEX 94/9/EC ............................................................ KEMA 10ATEX0053 X
IECEx ............................................................................. IECEx KEM 10.0022X
c FM us ......................................................................... 3038267-C
INMETRO ..................................................................... NCC 12.1309 X
GOST Ex
Functional safety:
exida, Cert No. ........................................................... PREl 070902 P0002 C05
SIL2 Certified & Fully Assessed acc. to IEC 61508
FMEDA report - www.prelectronics.com
of span = of the currently selected measurement range

Configuration of sensor error check

Sensor error check:
Device:
Configuration
Sensor error detection:
ERR.ACT=NONE - OUT.ERR=NONE.
OFF
9116
Else:
ON
12