LERBAKKEN 10, 8410 ROENDE DENMARK
Hazardous area
Zone 0, 1, 2, 20, 21, 22
4-20 mA
Loop-powered
transmitter
Module 9116B 1/2
Terminal 54-52
Ui
30 V
Ii
120 mA
Pi
900 mW
Ci
3 nF
Li
2 μH
Module 9116B1
Term. 54-52; 51-52
Uo
28 V
Io
93 mA
Po
650 mW
Module 9116B2
Term. 54-52; 51-52
Uo
21.4 V
Io
93 mA
Po
650 mW
Revision date:
2012-07-04
38
-20 ºC ≤Ta ≤ +60ºC
+
T
-
Group
Co
Lo
IIC
80 nF
4 mH
IIB
640 nF
16 mH 218 μH/Ω
IIA
2.1 μF
32 mH 436 μH/Ω
Group
Co
Lo
IIC
0.16 μF
4 mH
IIB
1.13 μF
16 mH 218 μH/Ω
IIA
4.15 μF
32 mH 436 μH/Ω
Version Revision
V6 R0
9116 - Product Version 9116-003
Non Hazardous area
or Zone 2
4501
54
34
53
33
52
32
51
31
44
14
43
13
42
12
41
11
9116
Power Rail
4501
54
34
53
33
52
32
51
31
44
14
43
13
42
12
41
11
9116
Power Rail
Lo/Ro
54 μH/Ω
Lo/Ro
54 μH/Ω
Prepared by:
9116QA01
Status relay, terminal (33,34)
Non hazardous area installation
Voltage max:
125 VAC / 110 VDC
Power max:
62.5 VA / 32 W
Current max:
0.5 A AC / 0.3 ADC
Zone 2 installation:
Voltage max:
32 VAC / 32 VDC
Power max:
16 VA / 32 W
Current max:
0.5 A AC / 1 A DC
Relay output, terminal (13,14)
Non hazardous area installation
Voltage max:
250 VAC / 30 VDC
Power max:
500 VA / 60 W
Current max:
2 A AC / 2 ADC
Zone 2 installation
Voltage max:
32 VAC / 30 VDC
Power max:
64 VA / 60 W
Current max:
2 A AC / 2 ADC
(terminal 11,12,13,14)
(terminal 31,32,33,34)
(terminal 91,92,93,94,95)