PR 4222 Configuration Manual

Universal i/f converter/modbus rtu
Hide thumbs Also See for 4222:

Advertisement

4 5 1 1 MO DB US RTU
Co nfig uratio n Manua l
Un i vers a l I / f co nve r t er
N o . 4 2 2 2 M C M 1 0 1 ( 1 4 4 5 )
F o r 4 5 1 1 d e v i c e s f r o m
s e r . n o : 1 4 1 5 9 0 0 0 1
4 2 2 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4222 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PR 4222

  • Page 1 4 5 1 1 MO DB US RTU Co nfig uratio n Manua l Un i vers a l I / f co nve r t er N o . 4 2 2 2 M C M 1 0 1 ( 1 4 4 5 ) F o r 4 5 1 1 d e v i c e s f r o m s e r .
  • Page 2: Table Of Contents

    4222 Configuration Parameter List ........
  • Page 3: Introduction

    INTRODUCTION This configuration manual contains the necessary information for configuring a PR 4222 device which is connected to a PR 4511 Modbus RTU enabler. Modbus is a “master-slave” system, where the “master” communicates with one or multiple “slaves”. The master typically is a PLC (Programmable Logic Controller), DCS (Distributed Control System), HMI (Human Machine Interface), RTU (Remote Terminal Unit) or PC.
  • Page 4: 4222 Configuration Parameter List

    4222 Configuration Parameter List Parameter Register Register Read/ Category Type Description Values Name Address Size Write UNSIGNED Defines the GENERAL DEVICE NUMBER 4222 = 16930 (0x4222) INTEGER actual device type UNSIGNED GENERAL DEVICE VERSION Product version INTEGER Password UNSIGNED GENERAL...
  • Page 5: General

    Frequency output Range with frequency selected: 0...25000000 FREQUENCY LOW UNSIGNED low value in mHz or Range with p/min. selected: 60...30000000 OUTPUT / PULSE LOW INTEGER 1/1000nds of pulses Range with p/hour selected: 3600...30000000 per min./hour/day Range with p/day selected: 86400...30000000 Frequency output Range with frequency selected: 0...25000000...
  • Page 6: 4222 Input Types And Ranges

    /min [blank] in/h ft/h µm mm/s µA l/min m/min mm/s gal/min 4222 Input Types and Ranges Input type Min. value Max. value Standard 0 mA 20 mA 10 V Pt10...Pt1000 -200°C +850°C IEC 60751 Ni50...Ni1000 -200°C +250°C DIN 43760 Lin.
  • Page 7: 4222 Process Parameter List

    4222 Process Parameter List Parameter Register Register Read/ Type Description Values Name Address Size Write Range for non-temperature input types: The measured value in 1/10 of °C/°F for DISPLAY LOW...DISPLAY HIGH temperature Input types, or the scaled DISPLAY VALUE 1000...
  • Page 8: 4511 Modbus Configuration Parameter List

    4511 Modbus Configuration Parameter List Parameter Register Register Read/ Type Description Values Name Address Size Write Enable Modbus communication. If disabled, 4511 ignores all frames sent ENABLE MODBUS 3000 INTEGER from the Modbus master and the only way to re-enable Modbus communication is by using the 4511 menu.
  • Page 9: 4511 Modbus Front Programming Parameter Menu

    4511 Modbus Front Programming Parameter Menu M" " (correct) (NO)         (YES)              Please note:     If no keys are activated for 1 minute, the 4511 display will return to the “Monitor” view without saving. ...