Parameter
Category
No.
Name
GENERAL
DEVICE NUMBER
0
GENERAL
DEVICE VERSION
1
GENERAL
PASSWORD
2
INPUT
INPUT TYPE
3
INPUT VOLTAGE
INPUT
4
RANGE
INPUT CURRENT
INPUT
5
RANGE
CONNECTION
INPUT
6
TYPE
INPUT
LIN RES LOW
7
INPUT
LIN RES HIGH
8
INPUT
TEMP UNIT
9
TEMP SENSOR
INPUT
10
TYPE
INPUT
PT TYPE
11
INPUT
NI TYPE
12
INPUT
TC TYPE
13
DISPLAy
DISPLAY UNIT
14
DISPLAy
DECIMAL POINT
15
DISPLAy
DISPLAY LOW
16
DISPLAy
DISPLAY HIGH
17
OUTPUT
OUTPUT TYPE
18
OUTPUT
OUTPUT UNIT
19
2
4222 Configuration Parameter List
Register
Register
Read/
Address
Size
Write
0
1
RO
1
1
RO
2
1
R/W
3
1
R/W
4
1
R/W
5
1
R/W
6
1
R/W
7
1
R/W
8
1
R/W
9
1
R/W
10
1
R/W
11
1
R/W
12
1
R/W
13
1
R/W
14
1
R/W
15
1
R/W
16
1
R/W
17
1
R/W
18
1
R/W
19
1
R/W
Type
Description
UNSIGNED
Defines the
INTEGER
actual device type
UNSIGNED
Product version
INTEGER
Password
UNSIGNED
for entering
INTEGER
configuration menu
Selected input type
(Voltage, Current,
UNSIGNED
Resistance,
INTEGER
Potentiometer,
Temperature)
Fixed input range for
UNSIGNED
voltage
INTEGER
measurements
Fixed input range for
UNSIGNED
current
INTEGER
measurements
Sensor
UNSIGNED
connection type
INTEGER
for RTD / resistance
measurements
Input range low for
UNSIGNED
Linear resistance meas-
INTEGER
urements
Input range high for
UNSIGNED
Linear resistance meas-
INTEGER
urements.
UNSIGNED
Temperature units
INTEGER
UNSIGNED
Temperature
INTEGER
sensor type
UNSIGNED
Pt value
INTEGER
(Pt10, Pt20, Pt50...)
UNSIGNED
Ni value
INTEGER
(Ni50, Ni100...)
UNSIGNED
Thermocouple type
INTEGER
(TCB, TCK...)
Units shown as display
UNSIGNED
units for non-tempera-
INTEGER
ture input types
Decimal point place for
UNSIGNED
display reading of non-
INTEGER
temperature input types
Low display range
for display reading of
INTEGER
non-temperature input
types.
High display range for
INTEGER
display reading of non-
temperature input types
Output type:
Programmable pulse is
available for:
UNSIGNED
Frequency < 500 Hz
INTEGER
Pulses < 30,000 p/m
< 1,800,000 p/hour
< 43,200,000 p/day
UNSIGNED
Output unit
INTEGER
4222MCM101
Values
4222 = 16930 (0x4222)
0
Range: 0
...9999
TEMP
=
0
POTM
=
1
LINR
=
2
CURR
=
3
VOLT
=
4
0...1 V
=
0
0.2...1 V
=
1
0...2.5 V
=
2
0.5...2.5 V =
3
0...5 V
=
4
1...5 V
=
5
0...10 V
=
6
2...10 V
=
7
0...20 mA
=
0
4...20 mA
=
1
2-wire
=
0
3-wire
=
1
4-wire
=
2
Range: 0...9998
Range: 1...9999
°C
=
0
°F
=
1
TC
=
0
Ni
=
1
Pt
=
2
Pt10
=
0
Pt20
=
1
Pt50
=
2
Pt100
=
3
Pt200
=
4
Pt250
=
5
Pt300
=
6
Pt400
=
7
Pt500
=
8
Pt1000
=
9
Ni50
=
0
Ni100
=
1
Ni120
=
2
Ni1000
=
3
TC type B
=
0
TC type E
=
1
TC type J
=
2
TC type K
=
3
TC type L
=
4
TC type N =
5
TC type R
=
6
TC type S
=
7
TC type T
=
8
TC type U
=
9
TC type W3 =
10
TC type W5 =
11
TC type Lr = 12
acc. to table 1
XXXX
=
0
X.XXX
=
1
XX.XX
=
2
XXX.X
=
3
Range: -1999...9999
Range: -1999...9999
DC 50%
=
0
Prog Pulse
=
1
Hz
=
0
p/min
=
1
p/hour
=
2
p/day
=
3
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
6
7
8
Show Quick Links
Quick Links:
4511 Modbus Parameter Settings
General
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Table of Contents
Related Manuals for PR 4222
Media Converter PR PREASY 4222 Manual
Universal i/f converter (51 pages)
Media Converter PR 4222 Product Manual
Universal i/f converter (27 pages)
Media Converter PR 3100 Manual
6mm series of isolators and converters (24 pages)
Media Converter PR 9116 Series Product Manual
Universal converter (50 pages)
Media Converter PR 3100 Series Manual
Isolators and converters (25 pages)
Media Converter PR 9113 Series Safety Manual
Temperature / ma converter (62 pages)
Media Converter PR 9113 Series Manual
Temperatur- / ma-konverter (62 pages)
Media Converter PR 5225 User Manual
Programmable f/l - f/f converter (35 pages)
Media Converter PR 9116 User Manual
Universal converter (79 pages)
Media Converter PR PRecon 5223 Manual
Programmable f/i - f/f converter (68 pages)
Media Converter PR 9113 Manual
Temperature / ma converter (65 pages)
Media Converter PR 9116 Safety Manual
Universal converter (79 pages)
Media Converter PR 5725 User Manual
Led frequency/pulse converter (28 pages)
Related Content for PR 4222
9100 Series If Any Parameter Is Found To Be Incorrect During Verification
PR 9100 Series
4222 Configuration / Operating The Function Keys
PR 4222
6 MM Series Dip-Switch Configuration
PR 6 MM Series
9113 Series If Any Parameter Is Found To Be Incorrect During Verification
PR 9113 Series
9113 Series If Any Parameter Is Found To Be Incorrect During Verification
PR 9113 Series
9116 Series Configuration Of Sensor Error Check
PR 9116 Series
9116 If Any Parameter Is Found To Be Incorrect During Verification
PR 9116
9116 If Any Parameter Is Found To Be Incorrect During Verification
PR 9116
9113 If Any Parameter Is Found To Be Incorrect During Verification
PR 9113
PREASY 4222 Configuration Of Sensor Error Detection
PR PREASY 4222
This manual is also suitable for:
4511
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL