Operating Instructions; Max/Min; Non-Contact Voltage Testing; Connecting Test Leads - Klein Tools CL800 Instruction Manual

600a ac/dc auto-ranging digital clamp meter
Hide thumbs Also See for CL800:
Table of Contents

Advertisement

Available languages

Available languages

enGliSH
function buttonS

MaX/Min

When the "MAX/MIN" button
8
of the Maximum and Minimum values and the difference between
the Maximum and Minimum values as the meter continues to take
samples.
1. When measuring, press "MAX/MIN" button
the Maximum value (MAX) and the Minimum value (MIN). If a
new Maximum or Minimum occurs, the display will update with
the new value.
2. Press "MAX/MIN" button
8
for more than one second to return to
normal measuring mode.

non-contact VoltaGe teStinG

Press the NCV button
to test for AC voltage using the integrated
12
non-contact voltage meter. Approach the conductor under test
leading with the sensing antenna
warning signals when AC voltage is detected.
teSt leaD HolDer
When working with test leads, one test probe may be mounted in the
test lead holder
to facilitate natural two-handed operation with the
13
clamp in one hand and a single test probe in the other.
8
CL800-1390106ART.indd 8-9
Dwg Name: CL800-1390106ART
Dwg No: 1390106
ECO No: 20622
Pkg Dwg Ref: 1290186
Color Reference: N/A
is pressed, the meter keeps track
8
to toggle between
14
. The meter delivers audible
Rev: A

operatinG inStructionS

connectinG teSt leaDS

Do not test if leads are improperly seated. Results could cause
intermittent display readings. To ensure proper connection, firmly
press leads into the input jack completely. Lead guard should be
flush with the meter's faceplate.
teStinG in cat iii / cat iV MeaSureMent locationS
Ensure the test lead shield is pressed firmly in place. Failure to use
the CAT III / CAT IV shield increases arc-flash risk.
5/32"
(4 mm)
teStinG in cat ii MeaSureMent locationS
CAT III / CAT IV shields may be removed for CAT II locations. This
will allow testing on recessed conductors such as standard wall
outlets. Take care not to lose the shields.
.7" (18 mm)
Dwg Name: CL800-1390106ART
Dwg No: 1390106
ECO No: 20622
Pkg Dwg Ref: 1290186
Color Reference: N/A
NO GAP
9
9/24/2015 2:40:01 PM
Rev: A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: