Temperature; Battery Replacement - Klein Tools CL800 Instruction Manual

600a ac/dc auto-ranging digital clamp meter
Hide thumbs Also See for CL800:
Table of Contents

Advertisement

Available languages

Available languages

enGliSH
operatinG inStructionS
2. Remove power from circuit.
3. Measure capacitance by connecting test leads across the capacitor.
The meter will auto-range to display the measurement in the most
appropriate range.
Black lead Red lead

teMperature

1. Insert K-type thermocouple (with adapter) into the VΩ
COM
jacks (observe polarity markings on thermocouple
4
and meter), and rotate function selector switch
Temperature
setting.
note: The meter defaults to Fahrenheit scale in this mode. To enter
Celsius scale, press the "SEL" button
appropriate icon (either °F or °C ) appears on the display.
note: The meter may be set to default to the Celsius scale by
powering-ON the meter from the OFF position with the Data Hold
& Backlight button
depressed. To re-set the default to the
6
Fahrenheit scale repeat the power-ON sequence.
2. To measure temperature, make contact between the
thermocouple tip and the object being measured. When
thermocouple tip and object are in thermal equilibrium, the
measurement on the display will stabilize. The meter will auto-
range to display the measurement in the most appropriate range.
range to display the measurement in the most appropriate range.
K-Type Thermocouple
(with adapter)
RED
BLACK
Adapter
remove thermocouple before switching meter to other
measurement functions.
the thermocouple included with the original purchase
is suitable for temperatures below 356°f / 180°c only.
to measure higher temperatures, a K-type thermocouple
with the appropriate measurement range should be used.
14
CL800-1390106ART.indd 14-15
Dwg Name: CL800-1390106ART
Dwg No: 1390106
ECO No: 20622
Pkg Dwg Ref: 1290186
Color Reference: N/A
and
5
to the
2
once. Ensure that the
9
Thermocouple
Rev: A
Maintenance

battery replaceMent

When
indicator is displayed on LCD, batteries must be replaced.
1. Remove screw from battery door.
2. Replace 2 x AAA batteries (note proper polarity).
3. Replace battery door and fasten securely with screw.
to avoid risk of electric shock, disconnect leads from any voltage
source before removing battery door.
to avoid risk of electric shock, do not operate meter while
battery door is removed.
Dwg Name: CL800-1390106ART
Dwg No: 1390106
ECO No: 20622
Pkg Dwg Ref: 1290186
Color Reference: N/A
15
9/24/2015 2:40:05 PM
Rev: A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl700

Table of Contents