Ac/Dc Current; Ac/Dc Voltage; Ac/Dc Ioz Voltage - Klein Tools CL800 Instruction Manual

600a ac/dc auto-ranging digital clamp meter
Hide thumbs Also See for CL800:
Table of Contents

Advertisement

Available languages

Available languages

enGliSH
operatinG inStructionS
ac/Dc current (leSS tHan 600a)
AC Current is measured by pressing the clamp trigger
the clamp
and placing it around a current-carrying wire. When
3
measuring, care should be taken to ensure that the clamp
completely closed with trigger
10
passes perpendicularly through the center of the clamp
with the arrow markings
with the arrow markings
.
.
11
11 11
To measure current:
1. Rotate the Function Selector switch
setting.
note: The meter defaults to AC measurement. Press the "SEL"
button
to toggle between AC and DC modes. The AC or DC icon
9
on the LCD indicates which mode is selected.
2. Place clamp
around wire. When measuring DC current, align the
3
polarity markings
on the clamp with the polarity of the wire to
15
avoid negative readings. The current measurement will be shown in
the display. The meter will auto-range to display the measurement in
the most appropriate range.
Disconnect test leads when measuring with the clamp.
note: If non-zero values are displayed prior to measuring in DC
current mode, an offset correction is required. With meter in DC
current mode, press and hold the "SEL" button
DC current ZERO function. Subsequent DC current measurements
automatically subtract the offset correction for improved accuracy.
10
CL800-1390106ART.indd 10-11
Dwg Name: CL800-1390106ART
Dwg No: 1390106
ECO No: 20622
Pkg Dwg Ref: 1290186
Color Reference: N/A
to open
10
is
3
fully released, and that the wire
in line
3
to the AC/DC current a
2
to activate the
9
Rev: A
operatinG inStructionS
ac/Dc VoltaGe (leSS tHan 1000V)
1. Insert RED test lead into VΩ jack
COM jack
, and rotate function selector switch
4
AC/DC voltage V
setting. The meter defaults to AC measurement.
To measure DC, press the "SEL" button
and DC modes. The AC or DC icon on the LCD indicates which
mode is selected. Note "ac" or "Dc" on the display.
Black lead Red lead
2. Apply test leads to the circuit to be tested to measure voltage.
The meter will auto-range to display the measurement in the
most appropriate range.
note: If "–" appears on the LCD, the test leads are being applied to
the circuit in reverse. Swap the position of the leads to correct this.
note: When in a voltage setting and the test leads are open,
readings of order mV may appear on the display. This is noise and
is normal. By touching the test leads together to close the circuit
the meter will measure zero volts.
ac/Dc loZ VoltaGe (leSS tHan 600V)
1. Insert RED test lead into VΩ jack
COM jack
, and rotate function selector switch
4
AC/DC LoZ voltage
setting. The meter defaults to AC
measurement. To measure DC, press the "SEL" button
toggle between AC and DC modes. The AC or DC icon on the LCD
indicates which mode is selected. Note "ac" or "Dc" on the display.
Black lead Red lead
2. Apply test leads to the circuit to be tested to measure voltage.
The meter will auto-range to display the measurement in the
most appropriate range.
Do not attempt to measure voltages greater than 600V
in loZ setting.
Dwg Name: CL800-1390106ART
Dwg No: 1390106
ECO No: 20622
Pkg Dwg Ref: 1290186
Color Reference: N/A
, and BLACK test lead into
5
to the
2
9
to toggle between AC
, and BLACK test lead into
5
to the
2
to
9
11
9/24/2015 2:40:02 PM
Rev: A