Continuity; Resistance Measurements; Diode Test; Frequency/Duty-Cycle - Klein Tools CL800 Instruction Manual

600a ac/dc auto-ranging digital clamp meter
Hide thumbs Also See for CL800:
Table of Contents

Advertisement

Available languages

Available languages

enGliSH
operatinG inStructionS

continuity

1. Insert RED test lead into VΩ jack
COM jack
, and rotate function selector switch
4
Continuity/Resistance/Diode-Test
note: The meter defaults to Continuity testing in this mode. Ensure
that the Continuity Testing icon
press the "SEL" button
repeatedly until the
9
2. Remove power from circuit.
3. Test for continuity by connecting conductor or circuit with test
leads. If resistance is measured less than 50Ω, an audible signal
will sound and display will show a resistance value indicating
continuity. If circuit is open display will show "ol".
Black lead Red lead
Do not attempt to measure continuity on a live circuit.

reSiStance MeaSureMentS

1. Insert RED test lead into VΩ jack
COM jack
, and rotate function selector switch
4
Continuity/Resistance/Diode-Test
note: The meter defaults to Continuity testing in this mode. Press
the "SEL" button
once to enter Resistance testing mode. The
9
Resistance icon will appear on the display.
2. Remove power from circuit.
3. Measure resistance by connecting test leads to circuit. The
meter will auto-range to display the measurement in the most
appropriate range.
Black lead Red lead
note: When in a Resistance setting and the test leads are open
(not connected across a resistor), or when a failed resistor is under
test, the display will indicate O.L. This is normal.
Do not attempt to measure resistance on a live circuit.
12
CL800-1390106ART.indd 12-13
Dwg Name: CL800-1390106ART
Dwg No: 1390106
ECO No: 20622
Pkg Dwg Ref: 1290186
Color Reference: N/A
, and BLACK test lead into
5
to the
2
setting.
is visible on the display. If not,
icon is shown.
, and BLACK test lead into
5
to the
2
setting.
Rev: A
operatinG inStructionS

DioDe teSt

1. Insert RED test lead into VΩ jack
COM jack
, and rotate function selector switch
4
Continuity/Resistance/Diode-Test
note: The meter defaults to Continuity testing in this mode. Press
the "SEL" button
twice to enter Diode testing mode. The Diode
9
icon
will appear on the display.
2. Touch test leads to diode. A reading of 200-800mV on display
indicates forward bias, "ol" indicates reverse bias. An open
device will show "ol" in both polarities. A shorted device will
show approximately 0mV.
Black lead Red lead
frequency / Duty-cycle
1. Insert RED test lead into VΩ jack
COM jack
, and rotate function selector switch
4

Frequency/Duty-Cycle

setting.
note: The meter defaults to Frequency testing in this mode. To enter
Duty-Cycle testing mode, press the "SEL" button
that the appropriate icon (either Hz or % ) appears on the display.
2. Measure by connecting test leads across the circuit.
Black lead Red lead
capacitance
1. Insert RED test lead into VΩ jack
COM jack
, and rotate function selector switch
4
Capacitance
setting.
Dwg Name: CL800-1390106ART
Dwg No: 1390106
ECO No: 20622
Pkg Dwg Ref: 1290186
Color Reference: N/A
, and BLACK test lead into
5
to the
2
setting.
and BLACK test lead into
5
to the
2
once. Ensure
9
, and BLACK test lead into
5
to the
2
13
9/24/2015 2:40:03 PM
Rev: A