Communication Connector(Cn3); Serial-Line Terminal Plug Cn3; Operation - BONMET SDL10A User Manual

Sd series
Table of Contents

Advertisement

3.5

Communication Connector(CN3)

■ RS-232
Termina
l
number
3
Receive data
5
Transmit data
1
GND
■ RS-485
Termina
l
number
7
Difference signal Data+
4
Difference signal Data-
8
GND
4.1
Operation steps
Item
Installation
Wiring
Preparation before

operation

Action confirmation
Parameters settings
Trial operation

Serial-line terminal plug CN3

Name
Symbol
Name
Symbol
Chapter 4 Operation
Please keep the motor shaft in a non-connection state, do not connect the motor
with mechanical system for servo action confirmation at first.
Connect servo drive with power and peripheral device
Please confirm all the necessary items before turn on the power. And check if
there is any alarm.
Operate in speed mode to test the servo drive and servo motor without any load
on the shaft.
Set parameters according to terms of use.
Connect motor with mechanical
protective functions (such as emergency stop and stroke limit) are working.
Check operation at both low speed and high speed.
BONMET motion GmbH/www.bonmet.com/www.bonmet.de
1
2
3
4
5
6
7
8
Function
RXD
Receive data signal.
TXD
Transmit data signal.
GND
Inhibit signal earth.
Function
Data+
Data+ terminal
Data-
Data- terminal
GND
Inhibit signal earth.
Content
systems,
turn on the power, and check whether
Description
Description
Reference
Chapter 2
Chapter 3
Chapter 4
Chapter 4
Chapter 5
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sdl10b

Table of Contents