24 V DC - DESIGN
10.1.

Electrical connection options

The following connection concepts are available for the electrical connection of the control head:
Cable gland
Connection left:
Connection right:
Fig. 13:
Connection concepts 24 V DC
10.2.

Electrical data

Power supply:
Connections:
Cable gland variant
Multi-pole connection variant
Power consumption (standby current): 30 mA at 24 V DC
36
Voltage, signals
external initiator
12 ... 28 V DC, residual ripple 10%
1 x M16 x 1.5 cable gland/SW22 - for power supply and signals,
(only for transportation safety device sealed with dummy plugs,
remove these before use!)
for cable diameter 5 ... 10 mm,
for wire cross-sections 0.14 ... 1.5 mm
1 x M16 x 1.5 cable gland/SW19 - connection option for external
initiator (sealed with dummy plug, remove these before use)
1 x M16 x 1.5 cable gland / SW22 with multi-pole connection (M12
plug according to IEC 61076-2-101, 12-pole on a cable of 8 cm
length for power supply and signals)
1 x M16 x 1.5 cable gland/SW19 - connection option for external
initiator (sealed with dummy plug, remove these before use)
English
Control Head Type 8681
24VDC-Design
Cable gland with multi-pole connection
(M12 plug according to IEC 61076-2-101, 12-pole)
Connection left:
Voltage, signals
Connection right:
external initiator
2