Carefully lift the electronics module upwards.
Installation procedure:
Carefully insert the entire electronics module into the recess in the lower housing part.
Plug the electronics module carefully onto the contact pins for the position measuring system.
Refasten the electronics module with the Torx T10 screw (torque 0.4 Nm).
Reattach the electrical connections.
Check DIP switch positions (4-switch block for color coding, 8-switch block on DeviceNet electronics module
for address and Baud rate) and set the previously noted switch settings, if necessary.
If necessary, set AS interface address and jumper positions.
If required, make settings again, read out by the PC service program, using the PC service program.
Perform Teach-In procedure (see Chapter "16.1. Setting the position measuring system (Teach-In)").
Be sure to work carefully and cautiously, so that the electronics are not damaged.
Close the housing following the instructions in Chapter "8. Opening and Closing the Housing".
20.3.

Changing the valves

According to the design, 0 to 3 valve modules have been installed in the control head. The valves have been
designed with the flow restriction equipment for intake and exhaust air and must be installed as a valve module.
Note:
Disassemble/assemble the valves in upright position, oth-
erwise there is a risk that the non-return valve will fall out!
Fig. 39:
Valve module
Procedure:
92
Valve module from above
English

ReplacementofComponentsandModules
Flow restriction screws
Torx screws (T10),
tightening torque:
1 Nm
Control Head Type 8681
Replacement o f C omponents a nd M odules