Hirschmann RS20 Reference Manual page 104

Ethernet gigabit switch
Hide thumbs Also See for RS20:
Table of Contents

Advertisement

CLI Commands: Base
refresh-interval
This command configures the digital inputs refresh interval. Each
input configured for event logging or SNMP traps is polled with this
interval.
<refresh-interval> The refresh interval is in the range of 1..10
seconds. Default: 1.
log-event
This command enables or disables the event logging of input status
changes for one or all digital inputs. Default: disable.
The input state will be checked according to the interval set with IO-
<refresh-interval>.
all Configure the IO-Module event logging for all digital inputs.
<slot/input>
digital input.
disable Disable event logging for digital input status changes.
enable
snmp-trap
This command enables or disables the sending of SNMP traps in
case of input status changes for one or all digital inputs. Default:
disable.
The trap will be sent to all SNMP trap receivers configured with
snmptrap.
The input state will be checked according to the interval set with IO-
<refresh-interval>.
all Configure the IO-Module SNMP trap for all digital inputs.
<slot/input>
digital input.
disable Disable SNMP traps for digital input status changes.
enable
104
Configure the IO-Module event logging for a single
Enable event logging for digital input status changes.
Configure the IO-Module SNMP trap for a single
Enable SNMP traps for digital input status changes.
4.6 Management Commands