MGC Release Notes - Version 9.0
Please be aware that upgrading the MGC-100 hardware may require upgrading the power
supplies and even the MGC chassis. Before upgrading the MGC-100, ensure that the power
consumption does not exceed the PS rating, and that the fuse rating is not exceeded when
using 110V AC supply. As a general guideline:
•
•
•
•
•
•
•
•
Control Unit Update Notice
The MCU Control unit must have at least 128 MB of memory to run MCU Version 9.0 and
later.
Version 9.0 Interoperability Table
The following table lists the devices with which Version 9.0 was tested.
Table 3: Version 9.0 Interoperability List
Device
Gatekeepers/Proxies
Polycom PathNavigator
Cisco gatekeeper
Radvision ECS gatekeeper
Tandberg gatekeeper
Microsoft LCS SIP proxy
Iptel proxy
ReadiManager SE200
Recorder
Polycom RSS 2000
4
Old chassis (shipped with 300 W PS units) has a 10 amp fuse, while the new chassis
(shipped with 450 W PS units) has 15 amps circuit breaker
Each board consumes up to 40W apart from video boards.
The Video+8 board consumes 75W, and the Video6 board (older video board)
consumes 55W.
The Control Unit consumes 30W.
Each older power supply unit (marked as PWR on its front panel) provides 300W (AC
& DC).
Each new power supply unit (marked as POWER on its front panel) provides 450W
(AC & DC).
The new 450W AC PS fits into an old AC chassis, but it is not recommended.
The new 450W DC PS does not fit into an old DC chassis.
Version
7.00.03.0204
12.3
3.5.2.5 (tested in version 7.5)
N2.0 (tested in version 7.01)
2005 ver. 2.0.5470.0
0.9.6
2.00.00.ER029