Table 9: Pending Issues (Continued)
#.
Category
13.
FTP
Gateway
14.
Gateway
15.
16.
General
H.239
17.
H.264
18.
19.
Interop
Interop
20.
Interop
21.
22.
IP
23.
IP
Description
FTP service on XPEK may stop
working, which affects system
functions, such as prevent the Logger
Diagnostic Files from opening, causing
the MGC Manager application to close.
When cascading VSW and CP
conferences via a Gateway and moving
the cascading link to and from a
conference, the cascading links' video
capabilities are suspended.
When calling from H323 endpoint to an
EQ on MGC V6 (used as an MCU)
through MGC V7 (used as GW
H323->H320), the call will fail.
Selecting the Enable Invite and the
Encryption parameters in the same
conference is not supported.
All the participants Statuses become
Faulty Connected for 1 second when
PVX endpoints send Content.
In Video Switching conference set to
H.264 and a line rate of 384Kbps, Sony
endpoints connect as secondary.
SONY HG-90 2.11 endpoint connects
as Secondary when connecting via
H323 to a VSW conference at a line
rate of 1152/1920 and the video
parameters are set to AUTO.
When connecting to a CP conference at
a line rate of 384 with encryption, FECC
and H.239, AETHRA endpoint cannot
display the Content.
When connecting to a VSW conference
at a line rate of 1152 Mbps, AETHRA
endpoint negotiates 2CIF and not HD
from the MCU decoder.
Connecting a service to a card during
card download card results in card
failure.
IP+48 card crashed after repetitive DSP
recovery and the assert "UNIT NOT
RESPONDING" was displayed.
Corrections, Pending Issues and Limitations
ID#
Remarks
20433
In the IP
Terminal, enter
restore_ftp. If
the system
displays an
indication that
the ftp cannot be
restored, reset
the MCU.
19469
20232
21097
21569
21207
VNGM-
1852
VNGM-
1863
VNGM-
1867
20747
Connect the
service after
software
download is
completed.
VNGM-
1808
VNGFE
-478
41
Need help?
Do you have a question about the MGC-25 and is the answer not in the manual?