Limitations - Polycom MGC-25 Release Notes

Hide thumbs Also See for MGC-25:
Table of Contents

Advertisement

CP Full Screen (1x1) Layout setting of Cascading Link is supported in CP conferences for
H.323, SIP and ISDN links in the following modes:
Classic and Quad Views Video Sessions including Auto Layout setting
Presentation Mode and Lecture Mode
Enabling the automatic CP 1x1 layout setting of the cascaded link:
Define the participant as a Casceded Link by setting the Node Type to MCU in the
Participants Properties - Advanced dialog box.
In the Section PEOPLE PLUS CONTENT, set the system.cfg flag:
ENABLE_AUTO_1x1_LAYOUT_FOR_CASCADED_LINK to YES.
When Auto Cascading functionality is enabled in the Entry Queue, the Profile and Ad
Hoc conference must have the same properties

Limitations

Cascaded Links are not supported in the following modes:
Conferences set to the Same Layout mode
COP and Software CP conferences
Connecting using MPI protocol
When a Gateway identifies itself as an MCU, endpoints behind the gateway connect in
a CP Cascade 1x1 layout. When the MCU functions as a gateway, the he system.cfg
flag - ENABLE_AUTO_1x1_LAYOUT_FOR_CASCADED_LINK must be set to
NO.
Version 9.0 Detailed Description - Video
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mgc-50Mgc-100

Table of Contents