6

TECHNICAL DATA

Part number
Voltage
Current range DC (marking)
Current range DC (cutting)
Output
(100% duty cycle) Power
Open circuit voltage (OCV)
Voltage (3-phase)
Current (3-phase)
Frequency
KVA
Input
Power
Power factor
Input fuse rec.
Dimensions lxwxh
Weight
7

INSTALLATION

7.1

General

7.2

Unpacking

Inspect for transit damage immediately upon receipt.
S
Remove all components from shipping container and check for loose parts in
S
container.
Inspect louvers for air obstructions.
S
bp12a1
FAILURE TO FOLLOW INSTRUCTIONS COULD LEAD TO DEATH,
INJURY OR DAMAGED PROPERTY. FOLLOW THESE INSTRUCTIONS
TO PREVENT INJURY OR PROPERTY DAMAGE. YOU MUST COMPLY
WITH LOCAL, STATE AND NATIONAL ELECTRICAL AND SAFETY
CODES.
- 17 -
EPP-360 460V, 60Hz
0558 006 832
200 VDC
10A to 36A
30A to 360A
72 kW
360 VDC
460V
115A RMS
60 Hz
91.6 KVA
82.5 KW
90.0%
150A
47.25"x23,75"x40.75"
1200 X 603 X 1035 mm
1085 Ibs
EPP-360 575V, CSA,
60Hz
0558 006 833
200 VDC
10A to 36A
30A to 360A
72 kW
360 VDC
575V
92A RMS
60 Hz
91.6 KVA
82.5 KW
90.0%
125A
47.25"x23,75"x40.75"
1200 X 603 X 1035 mm
1085 Ibs