7.5

Output connections

7.5.1

Output cables (customer supplied)

Choose plasma cutting output cables (customer supplied) on the basis of one 4/0
AWG, 600 volt insulated copper cable for each 400 amps of output current.
NOTICE
7.5.2

Output connection procedure

1. Open access panel on the lower front of the power source.
2. Thread output cables through the openings at the bottom of the power source
immediately behind the front panel.
3. Connect cables to designated terminals mounted inside the power source using
UL listed pressure wire connectors.
4. Close front access panel.
Front access panel closed
bp12a1
ELECTRIC SHOCK CAN KILL! DANGEROUS VOLTAGE AND
CURRENT! ANY TIME WORKING AROUND A PLASMA POWER
SOURCE WITH COVERS REMOVED:
- DISCONNECT POWER SOURCE AT THE LINE (WALL)
DISCONNECT.
- HAVE A QUALIFIED PERSON CHECK THE OUTPUT BUS BARS
(POSITIVE AND NEGATIVE) WITH A VOLTMETER.
Do not use 100 volt insulated welding cable.