MAINTENANCE

9.1

General

9.2

Cleaning

Regularly scheduled cleaning of the power source is required to help keep the unit
running trouble free. The frequency of cleaning depends on environment and use.
1. Turn power off at wall disconnect.
2. Remove side panels.
3. Use low pressure compressed dry air, remove dust from all air passages and
components. Pay particular attention to heat sinks in the front of the unit. Dust
insulates, reducing heat dissipation. Be sure to wear eye protection.
bp12a3
ELECTRIC SHOCK CAN KILL!
SHUT OFF POWER AT THE LINE (WALL) DISCONNECT BEFORE
ATTEMPTING ANY MAINTENANCE.
EYE HAZARD WHEN USING COMPRESSED AIR TO CLEAN.
* WEAR APPROVED EYE PROTECTION WITH SIDE SHIELDS
WHEN CLEANING THE POWER SOURCE.
* USE ONLY LOW PRESSURE AIR.
Maintenance on this equipment should only be performed by
trained personnel.
ELECTRIC SHOCK HAZARD!
BE SURE TO REPLACE ANY COVERS REMOVED DURING
CLEANING BEFORE TURNING POWER BACK ON.
Air restrictions may cause EPP-360 to over heat. Thermal swit-
ches may be activated causing interruption of function.
Do not use air filters on this unit.
Keep air passages clear of dust and other obstructions.
- 34 -