Help code list

01
LINE VOLT, IDLE
02
LINE VOLT, CUTTING
03
CONTROL BIAS
04
THERMAL (SWITCH
OPEN)
05
START ON POWER UP
06
FAIL TO FIRE
Code
Error number displays and their meaning for the EPP -360 power supply.
01
+/- 15% deviation in the idle mode is exceeded.
02
Line voltage during cut drops by more than 20 %.
03
Problem with the bias supplies on the control board. The +15 and -15 volt supplies are not
balanced, board should be replaced.
04
Thermal switch has opened. Unit is disabled until overheated component cools down. Look
for fans not working or restrictions on input or output louvers
05
The start switch from the CNC was already on when the power source was powered up. Unit
will not be functional until start signal is removed and then reapplied.
06
Ignition did not take place during the 10 seconds allowed for arc ignition.
Note: This should rarely occur since the CNC has a much shorter time allowed for the
ignition time and will reset the power source to idle.
08
Electrode current was present before the PWM was enabled. Most likely caused by an
electrode to nozzle short on the torch.
09
Open circuit voltage in idle mode was over 40 volts. Possible cause leaky IGBTs, faulty
PWM drive
10
Open circuit voltage is over 70 volts when unit is powered up. Possible cause leaky IGBT's,
faulty PWM.
12
Shut down due to single phasing. Fuse blown in supply line circuit.
13
Open circuit voltage did not reach 300 volts in the allowed time. Check PWM circuit & E-Stop
on J1.
14
Ambient temperature exceeded 55 C in control enclosure.
15
Bus voltage did not reach 100 volts during the allowed time. Bus charge relay or surge
limiting resistors defective
17
IGBT driver board error.
18
Cutting voltage fell below 70 volts during cutting or below 40 volts during marking.
19
Master is requested to engage slave power supply but slave is not present.
20
Open circuit voltage detected before PWM was engaged.
113
Error detected in slave power supply.
bp12a3
Help codes
08
TORCH ERROR
09
OCV OVER 40V, IDLE
10
OCV OVER 70V,
STARTUP
12
1Ф OPERATION,
SHUTDOWN
13
OCV FAILURE
14
AMBIENT TEMP
- 36 -
15
BUS CHARGER FAILURE
17
IGBT DRIVER ERROR
18
CUT/MARK VOLTAGE
TOO LOW
19
SLAVE P/S NOT
DETECTED
20
SHORTED IGBT, BUS
CHARGED
113 SLAVE P/S ERROR