Marking With Two Parallel Epp -360'S - ESAB EPP-360 Instruction Manual

Table of Contents

Advertisement

Connections for parallel installation of two EPP-360 power sources with only one
power source in operation:
EPP-360
Supplemental power source
work
(+)
Disconnect negative connection from
2-4/0 600 V
positive leads
to workpiece
7.6.2

Marking with two parallel EPP -360's

Two EPP-360's, connected in parallel, and can be used for marking down to 10A
and cutting from 30A up to 720A.
Operation of two parallel EPP-360's:
Provide start/stop, Cut/Mark, "HI CURRENT" logic signals and either logic or analog
inputs to control the pilot current signals to primary unit for both cutting and marking.
When marking, both power sources are powered up, but the mark signal disables
the output of the supplemental power source.
bp12a1
electrode
(-)
P/S parallel control cable
supplemental power source and
insulate to convert from two to one
power source
- 23 -
EPP-360
Primary power source
work
electrode
(+)
(-)
2 - 4/0 600V
negative leads in arc starter box
(h.f. generator)
Control cable to
water cooler
© ESAB AB 2010

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents