Low Voltage Operation - Toshiba VF-S15 Instruction Manual

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for VF-S15:
Table of Contents

Advertisement

 Table of input terminal functions 3
Function
Code
No.
100
RS
101
RSN
104
FCHG
105
FCHGN
106
FMTB
107
FMTBN
108
CMTB
109
CMTBN
110
PWE
111
PWEN
120
FSTP1
121
FSTP1N
122
FSTP2
123
FSTP2N
134
TVS
135
TVSN
136
RSC
137
RSCN
140
SLOWF
141
SLOWFN
142
STOPF
143
STOPFN
144
SLOWR
145
SLOWRN
146
STOPR
147
STOPRN
11
148 to 151
152
MOT2
153
MOT2N
158
RES2
159
RES2N
200
PWP
201
PWPN
PRWP
202
203
PRWPN
*1: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
*2: These functions are cannot be assigned to Always active function selection 1 to 3 (f104, f108, f110).
Note 1: Function No. that are not described in the table above are assigned "No function".
Function
Run/Stop command
Inversion of run/Stop command
Frequency setting mode forced switching
Inversion of frequency setting mode forced
switching
Frequency setting mode terminal block
Inversion of frequency setting mode terminal
block
Command mode terminal block
Inversion of command mode terminal block
Parameter editing permission
Inversion of parameter editing permission
Fast stop command 1
Inversion of fast stop command 1
Fast stop command 2
Inversion of fast stop command 2
Traverse permission signal
Inversion of traverse permission signal
Low voltage operation signal
Inversion of low voltage operation signal
Forward deceleration
Inversion of forward deceleration
Forward stop
Inversion of forward stop
Reverse deceleration
Inversion of reverse deceleration
Reverse stop
Inversion of reverse stop
Factory specific coefficient
No.2 motor switching
(AD2+VF2+OCS2)
Inversion of No.2 motor switching
(AD2+VF2+OCS2)
Reset command 2 *2
Inversion of reset command 2 *2
Parameter editing prohibition
Inversion of parameter editing prohibition
Parameter reading prohibition
Inversion of parameter reading prohibition
Action
ON: Run command
OFF: Stop command
Inversion of RS
ON: f207 (f200=0)
OFF: fmod
Inversion of FCHG
ON: Terminal block (VIA) enabled
OFF: Setting of 
Inversion of FMTB
ON: Terminal block enabled
OFF: Setting of 
Inversion of CMTB
ON: Parameter editing permitted
OFF: Setting of 
Inversion of PWE
ON: Dynamic quick deceleration command
OFF: Forced deceleration canceled
(Note that operation is resumed when forced deceleration is canceled)
Inversion of FSTP1
ON: Automatic deceleration
OFF: Forced deceleration canceled
(Note that operation is resumed when forced deceleration is canceled)
Inversion of FSTP2
ON: Permission signal of traverse operation
OFF: Normal operation
Inversion of TVS
ON: Low voltage operation
OFF: Low voltage operation canceled
Inversion of RSC
ON: Forward operation with f383 frequency
OFF: Normal operation
Inversion of SLOWF
ON: Forward stop, OFF: Normal operation
Inversion of STOPF
ON: Reverse operation with f383 frequency
OFF: Normal operation
Inversion of SLOWR
ON: Reverse stop, OFF: Normal operation
Inversion of STOPR
-
ON: No.2 motor
(=0, , , ,  (thr when
f632=2 or 3), , , , )
OFF: No.1 motor (Set value of , , , , ,
, , , )
Inversion of MOT2
ON: Trip reset
Inversion of RES2
ON: Parameter editing prohibited
OFF: Setting of 
Inversion of PWP
ON: Parameter reading / editing prohibited
OFF: Setting of 
Inversion of PRWP
K-32
E6581611
Reference
7.2.1
6.2.1
6.34.1
6.1.4
6.40
6.17
6.22.2
*1
6.8.1
13.2
6.34.1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents