Toshiba VF-S15 Instruction Manual page 170

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for VF-S15:
Table of Contents

Advertisement

 Input/output parameters 2
Communication
Title
Function
No.
0470
VIA input bias

0471
VIA input gain

0472
VIB input bias

0473
VIB input gain

0474
VIC input bias

0475
VIC input gain

 Torque boost parameters 2
Communications
Title
Function
No.
0480
Motor specific

coefficient 6
0485
Motor specific

coefficient 7
0490
Motor specific

coefficient 8
0495
Motor specific

coefficient 9
0499
Motor specific

coefficient 10
*4: Motor specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
 Acceleration/deceleration time parameters
Communication
Title
Function
No.
0500
Acceleration time 2

0501
Deceleration time 2

0502
Acceleration/decel

eration 1 pattern
0503
Acceleration/decel

eration 2 pattern
0504
Acceleration/decel

eration selection
(1, 2 , 3)
(Panel keypad)
0505
Acceleration/decel

eration 1 and 2
switching
frequency
0506
S-pattern lower-

limit adjustment
amount
0507
S-pattern upper-

limit adjustment
amount
0510
Acceleration time 3

*8: These parameters can be changed to 0.01s unit by setting f519=1.
Minimum
setting unit
Unit
Adjustment range
Panel/Commun
ication
-
1/1
0-255
-
1/1
0-255
-
1/1
0-255
-
1/1
0-255
-
1/1
0-255
-
1/1
0-255
Minimum
setting unit
Unit
Adjustment range
Panel/Commun
ications
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Minimum
setting unit
Unit
Adjustment range
Panel/Commun
ication
s
0.1/0.1
0.0-3600 (360.0) *8
s
0.1/0.1
0.0-3600 (360.0) *8
-
-
0: Linear
1: S-pattern 1
2: S-pattern 2
-
-
-
-
1: Acceleration/deceleration 1
2: Acceleration/deceleration 2
3: Acceleration/deceleration 3
Hz
0.1/0.01
0.0 (disabled)
0.1-
%
1/1
0-50
%
1/1
0-50
s
0.1/0.1
0.0-3600 (360.0) *8
K-15
E6581611
Default
User
Reference
setting
setting
128
6.10.3
128
128
128
128
128
Default
User
Reference
setting
setting
-
* 4
-
-
-
-
Default
User
Reference
setting
setting
10.0
6.27.2
10.0
0
6.27.1
0
6.27.2
1
0.0
10
6.27.1
10
10.0
6.27.2
11

Hide quick links: