Speed Instruction (Analog Signal) Settings From External Devices - Toshiba VF-S15 Instruction Manual

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for VF-S15:
Table of Contents

Advertisement

7.3
Speed instruction (analog signal) settings from
external devices
Function of analog input terminals can be
selected from four functions (external
potentiometer, 0 to 10Vdc, 4 (0) to 20mAdc,
-10 to +10Vdc).
The selective function of analog input
terminals gives system design flexibility.
The maximum resolution is 1/1000.
Default settings of slide switch SW1and SW2
are as follows;
SW1: PLC side, SW2: VIB side and S3 side.
Refer to page B-11 to 13 for details.
7
 Analog input terminal function settings
Terminal
symbol
VIA
VIB
VIC
VIA to VIC
*1: Default setting values vary depending on the setup menu setting. Refer to section 11.5.
Note1) When stable operation cannot be attained because of frequency setting circuit noise, increase the value of
f.
Note 2) Refer to section 5.8 when switching between two types of analog signals.
Title
Function

VIA input point 1 setting
VIA input point 1 frequency

VIA input point 2 setting


VIA input point 2 frequency
VIB input point 1 setting

VIB input point 1 frequency

VIB input point 2 setting

VIB input point 2 frequency

VIC input point 1 setting

VIC input point 1 frequency

VIC input point 2 setting

VIC input point 2 frequency

Analog input filter

[Control terminal block]
SW2
VIB
S4
S3
PTC
VIA
CC
VIC
PP
VIB
OUT
CC
NO
P24
F
Adjustment range
0 - 100%
0.0 - 500.0Hz
0 - 100%
0.0 - 500.0Hz
-100 - +100%
0.0 - 500.0Hz
-100 - +100%
0.0 - 500.0Hz
0 - 100%
0.0 - 500.0Hz
0 - 100%
0.0 - 500.0Hz
2 - 1000 ms Note 1)
G-12
E6581611
SW1
SINK
SOURCE
PLC
S3
FM
FLA
FLB
FLC
RY
+24
R
CC
+SU
S2
RES
S1
Default setting
0
0.0
100
*1
0
0.0
100
*1
20
0.0
100
*1
64
RC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents