Toshiba VF-S15 Instruction Manual page 177

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for VF-S15:
Table of Contents

Advertisement

Communication
Title
No.
0711

0712

0713

0714

0715

0716

0717

0718

11
0719

0720

0721

0724

Minimum
setting unit
Function
Unit
Panel/Commun
ication
Status monitor 1
-
Status monitor 2
-
Status monitor 3
-
Status monitor 4
-
Status monitor 5
-
Status monitor 6
-
Status monitor 7
-
Status monitor 8
-
Selection of
-
operation
command clear
Initial extension
-
panel display
selection
Panel stop pattern
-
Operation
-
frequency setting
target by setting
dial
Adjustment range
-
0: Output frequency (Hz/free unit)
1: Output current (%/A)
2: Frequency command value
(Hz/free unit)
3: Input voltage (DC detection) (%/V)
4: Output voltage (command value) (%/V)
-
5: Input power (kW)
6: Output power (kW)
7: Torque (%)
8: -
9: Motor cumulative load factor
10: Inverter cumulative load factor
-
11: PBR (Braking resistor) cumulative
load factor
12: Stator frequency (Hz/free unit)
13: VIA input value (%)
14: VIB input value (%)
15 to 17: -
-
18: Arbitrary code from communication
19: -
20: VIC input value (%)
21: Pulse train input value (pps)
22: -
23: PID feedback value (Hz/free unit)
-
24: Integral input power (kWh)
25: Integral output power (kWh)
26: Motor load factor (%)
27: Inverter load factor (%)
28: Inverter rated current (A)
-
29: FM output value (%)
30: Pulse train output value (pps)
31: Cumulative power on time (100
hours)
32: Cumulative fan operation time
(100 hours)
-
33: Cumulative operation time (100
hours)
34: Number of starting (10000 times)
35: Forward number of starting
(10000 times)
36: Reverse number of starting
-
(10000 times)
37: Number of trip (times)
38, 39: -
40: Inverter rated current (Carrier
frequency corrected)
41 to 51: -
52: Frequency command value /
output frequency (Hz/free unit)
-
0: Clear at coast stop and retained at
moff.
1: Retained at coast stop and
moff.
2: Clear at coast stop and moff.
3: 2+ clear when cmod is changed
-
0-52 (Same as f710)
-
0: Deceleration stop
1: Coast stop
-
0: Panel frequency ()
1: Panel frequency () + Preset
speed frequency
K-22
E6581611
Default
User
Reference
setting
setting
2
6.34.6
8.2.1
8.3.2
1
3
4
5
6
27
0
1
6.34.8
0
6. 34.5
0
6. 34.9
0
5.7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents