3) Control circuit terminal block
VIA
PP
1
CC
NO
Wire size
Recommended ferrule
Using ferrule to be improved efficiency and reliability of wiring is recommended.
*2
*2
*1: Crimping pliers
*2: These ferrules enable practical crimping of two wires in a ferrule.
The control circuit terminal block is common to all equipment.
SW2
SW1
VIB CC VIC S3 FM
FLA FLB FLC RY RC
OUT P24 F
R CC +SU +24
RES S1 S2
Recommended
Screw size
tightening torque
0.5 Nm
M3 screw
4.4 lbin
Refer to section 2.3.2 for details about all terminal functions.
Conductor
Solid
0.3-1.5mm
Stranded
Wire size
2
mm
(AWG)
0.34 (22)
0.5 (20)
0.75 (18)
1 (18)
1.5 (16)
2 X 0.5 (-)
2 X0.75 (-)
CRIMPFOX ZA3 (PHOENIX CONTACT)
CT1 (Dinkle International.,Ltd)
Screw for removable control terminal block
RS485 connector
Stripping length: 6 (mm)
Screwdriver: Small-sized flat-blade screwdriver
(Blade thickness: 0.5 mm, blade width: 3.5 mm)
1 wire
2
(AWG 22-16)
Type
PHOENIX CONTACT
AI 0.34-6TQ
AI 0.5-6WH
AI 0.75-6GY
AI 1-6RD
AI 1.5-8BK
AI TWIN2 X 0.5-8WH
AI TWIN2 X 0.75-8GY
A-20
E6581611
SW1
SW2
SINK SOURCE
VIB
S4
S3
PTC
PLC
2 wires of same size
2
0.3-0.75mm
(AWG 22-18)
Dinkle International.,Ltd
DN00306
DN00506
DN00706
DN01006
DN01508
DTE00508
DTE00708

Hide quick links: