 Assign one type of function to an output terminal
Terminal
Title
symbol
RY-RC
 Output terminal selection 1A
OUT
 Output terminal selection 2A
FL
 Output terminal selection 3
(A, B, C)
Note 2) When assigning 1 type of function to the RY-RC terminal, set only .
Leave parameter  as the default setting ( = ).
Note 3) When assigning 1 type of function to the OUT terminal, set only .
Leave parameter  as the default setting ( = ).
 Assign two types of functions to the output terminal (RY-RC, OUT)
Terminal
Title
symbol

RY-RC


OUT

RY-RC,

OUT
Note 4)  and  are active only when  = : Logic output (default). 
Function is inactive when  = : Pulse train output is set.
Function
Function
Output terminal
selection 1A
Output terminal
selection 1B
Output terminal
selection 2A
Output terminal
selection 2B
0:  and 
 and 
1:  or 
 and 
Output terminal logic
selection
2:  and 
 or 
3:  or 
 or 
G-7
Adjustment range
Default setting
4 (Low-speed detection
signal)
6 (Output frequency
0 - 255
attainment signal)
10 (Fault signal)
Adjustment range
4 (Low-speed
detection signal)
255 (Always ON)
0 - 255
6 (Output frequency
attainment signal)
255 (Always ON)