S-Register List; 3800 Series S-Registers - Paradyne 3800 User Manual

Comsphere 3800 series
Hide thumbs Also See for 3800:
Table of Contents

Advertisement

S-Register List

S-registers affect the operating parameters of the
3800 Series modems. S-registers are only applicable when
the DTE Dialer Type configuration option is set for AT.
(See &Mn command.)
Table 14-2 lists all S-registers supported by the
3800 Series modems. The first column lists the S-register.
The second column lists all possible values for that
register. The third column lists the key sequence used to
enter the equivalent from the front panel. Use this column
to reference commands in Chapter 9 if further description
is necessary.
S-Register
S0
Auto-Answer Ring Number
Register determines number of rings the modem will count before
automatically answering a call.
Enter zero (0) if you do not want the modem to automatically answer any
calls. Otherwise, enter a value from 1 to 255 for the number of rings to
count before answering.
Factory setting is 1.
S2
AT Escape Character
Register determines ASCII value used for escape sequence to enter
Command mode from Data mode.
Enter a value from 1 to 127 for the escape character. Any value greater
than 127 causes the modem to disable the escape sequence. When the
escape sequence is disabled, the modem cannot return to Command
mode until the call is disconnected.
Factory setting is 43 (+ key).
S3
Carriage Return Character
Register determines ASCII value used as the carriage return (Return
key). This character is used to end command lines and result codes.
Enter a value from 0 to 127 for the command end character.
Factory setting is 13 (carriage return key).
NOTE: The &W command used to save this change must be on a
separate line. This ensures both that the change is intentional,
and that the DTE can enter the new character.
3810-A2-GB30-30
S-Register Format
S-registers can be displayed and/or modified when the
modem is in Command mode. To display the value of an
S-register, issue the following command:
TYPE:
Where:
PRESS:
To modify the value of an S-register, issue the
following command:
TYPE:
Where:
PRESS:
In Table 14-2, the value for n is listed in the S-register
column, and the value for r is listed in the Description
column.
Table 14-2
(1 of 12)

3800 Series S-Registers

Description
September 1998
AT Command Set and S-Registers
ATSn?
n is the register number
Enter
ATSn=r
n is the register number, and r is the new
value
Enter
Front Panel Branch
Configure\Edit\Line Dialer
Configure\Edit\DTE Dialer
Configure\Edit\DTE Dialer
14-15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3810Comsphere 3811Comsphere 3820

Table of Contents