Paradyne 3800 User Manual page 60

Comsphere 3800 series
Hide thumbs Also See for 3800:
Table of Contents

Advertisement

Options
The Options Status function displays all optional
firmware features currently installed in the modem (for
example, V.29, V.33, and dial network management). If no
firmware options are installed, None_Installed appears on
the LCD.
To access Options from the Status branch, make the
following sections:
Status:
RS366A
F1
F2
Press the
key until Options appears. Select
Options.
Options' Status
V.29
F1
F2
If optional features are installed in the modem, they
appear on the LCD's bottom line. If other features are
installed, press the
key to scroll other features into
view.
Record
Record is a troubleshooting tool used by the end user in
conjunction with support personnel. This function allows
the end user to retrieve and report any sequence faults to
support personnel. A sequence fault is an irregular or
unexpected event.
There are two selections under Record: Display and
Clear. Display allows up to eight sequence fault messages
that have been recorded by the modem to be displayed on
the LCD. If no sequence faults have occurred, then
Modem O.K. appears.
Clear is used to remove all sequence fault messages
from nonvolatile memory and the LCD.
3810-A2-GB30-30
Options
F3
>
V.33
F3
September 1998
To access Record from the Status branch, make the
following selections:
Status
Options
F1
F2
Press the
key until Record appears. Select Record.
Record Status
Display
Clear
F1
F2
To display sequence faults, select Display.
Record Number 1
Modem O.K.
F1
F2
The LCD displays the first sequence fault field.
(Sequence fault fields range from 1 to 8 and are identified
by a number in the upper right corner.) Press the
to view the remaining fields. The message Modem O.K.
appears if no sequence faults have occurred.
To remove sequence fault records from both the LCD
and nonvolatile memory, select Clear. The message
Modem O.K. appears.
To exit this function and remain in the Status branch,
press the
key. To exit and return to the Top-Level
menu, press the
key.
AT Command Equivalent
The AT command I17 displays the last sequence fault
record.
Status Branch
<
Record
F3
F3
F3
key
7-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3810Comsphere 3811Comsphere 3820

Table of Contents