Dlci Alarm Defaults - Paradyne Area - Paradyne 9820 User Manual

Framesaver slv in-line monitors
Hide thumbs Also See for 9820:
Table of Contents

Advertisement

DLCI Alarm Defaults – Paradyne Area
These alarms apply to all DLCIs on the network interface and can be created
during RMON initialization or when a DLCI is created. They are put into the
Paradyne alarm area.
Table B-12. DLCI Alarm Defaults – Paradyne Area (1 of 2)
Sample
Item
Type
DLCI Inactive
D
Seconds
Missing Latency
D
Responses
Rx FECNs
D
Rx BECNs
D
Congested Seconds D
Frames Dropped by
D
Network
9820-A2-GB20-20
2
1
MIB/Tag/OID
MIB: pdn_FrExt.mib (E)
Tag: devFrExtDlciStsInactive-
Secs
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.2.1.2.I.D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtDlciMissedSLVs
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.1.1.23.I.D
MIB: FR DTE MIB
(RFC 2115)
Tag: frCircuitReceivedFECNs
OID: .1.3.6.1.2.1.10.32.2.1.
4.I.D
MIB: FR DTE MIB
(RFC 2115)
Tag: frCircuitReceivedBECNs
OID: .1.3.6.1.2.1.10.32.2.1.
5.I.D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtDlciSts-
CongestedSecs
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.2.1.6.I.D
MIB: pdn_FrExt.mib (E)
Tag: devFrExtDlciNetDropFr
OID: .1.3.6.1.4.1.1795.2.24.2.
6.9.4.1.1.20.I.D
June 2000
SNMP MIBs and Traps, and RMON Alarm Defaults
Event
Interval
Type
900 secs
Rising
(15 mins)
900 secs
Rising
(15 mins)
60 secs
Rising
(1 min)
60 secs
Rising
(1 min)
60 secs
Rising
(1 min)
60 secs
Rising
(1 min)
Rising
Falling
Threshold
Threshold
Default
Default
1
1
5
5
1
1
1
1
5
5
1
1
B-19