FTP Operation

Transferring Collected Data

7-6
SLV user history statistics and LMI packet capture data can be uploaded to an
NMS or a Network Associates Sniffer using FTP, which is faster than other
methods. For Models 9820, 9820-2M, and 9820-8M, the rate at which the data
file is transferred is the rate set by the FTP Max Receive Rate (Kbps) option (see
Table 4-13,
Telnet and FTP Session Options
Options ). For Model 9820-45M, the rate is fixed.
NOTE:
Use your NMS application to FTP and view transferred statistics and packet
data; the data files are not in user-readable format. LMI packet capture data
can also be viewed via the LMI Trace Log (see
from the Menu-Driven User Interface
additional information).
Procedure
To retrieve data:
1. Initiate an FTP session to the device from which SLV statistics or packet data
will be retrieved.
2. Type bin to enter binary transfer mode.
3. Type hash to enter hash mode if you want to monitor the progress of the
upgrade, provided this function is supported by your equipment.
4. Type cd data to change to the data directory.
If retrieving . . .
SLV statistics
LMI packet capture data
5. Close the FTP session.
SLV statistics and/or LMI Packet Capture data are now available for reporting.
June 2000
in Chapter 4, Configuration
Viewing Captured Packets
in Chapter 8, Troubleshooting , for
Then . . .
Perform a get of the uhbcfull.dat file.
File Transfer Complete – Transfer was
successful.
File Transfer Failed – Transfer was not
successful. Try again or end the session.
Stop the LMI Packet Capture Utility.
Main Menu
Control
LMI packet capture data is not available (readable)
when the LMI Packet Capture Utility is Active.
Perform a get of the lmitrace.syc file.
One of the following responses appears:
– File Transfer Complete
– File Transfer Failed
– Permission Denied – The LMI Packet
Capture data was not readable, or was a null file.
Stop the LMI Packet Capture Utility and try
again.
LMI Packet Capture Utility