Troubleshooting Management Link Feature

LMI Packet Capture Utility Feature

9820-A2-GB20-20
A dedicated troubleshooting management link is available to help service
providers isolate device problems within their networks. This feature allows Telnet
or FTP access to the unit on this link and troubleshooting over this link is
essentially transparent to customer operations. No alarms or SNMP traps are
generated to create nuisance alarms for the customer.
Configuring Node IP Information
See
additional information about this feature.
A packet capture utility has been provided to aid with problem isolation when LMI
errors are detected. Using this utility, any enabled frame relay link on the user
data port or network interface can be selected. The utility captures any LMI
packets sent or received and writes them to a data file called lmitrace.syc in the
system's data directory so the data can be uploaded and transferred to a Network
Associates Sniffer for analysis.
The LMI Trace Log also provides access to captured packet information. See
Viewing Captured Packets from the Menu-Driven User Interface
information on this feature.
Procedure
To use this utility:
1. Select the LMI Packet Capture Utility.
Main Menu
Control
2. Select an enabled frame relay link, or Capture Interface, either Net1-FR1
or Port-1.
3. Start packet capture.
While capturing data, the status is Active. Packets in Buffer indicates the
number of packets that have been captured. Up to 8000 packets can be held.
When the buffer is full, the oldest packets will be overwritten.
4. To stop the utility, press Enter. The field toggles back to Start.
5. Upload the data file holding the collected packets to a diskette so the
information can be transferred to a Network Associates Sniffer for
debugging/decoding.
Transferring Collected Data
See
information about this feature.
June 2000
in Chapter 4, Configuration Options , for
LMI Packet Capture Utility
in Chapter 7, FTP Operations , for additional
Troubleshooting
for additional
8-5