Clearing Performance Statistics - Paradyne 9820 User Manual

Framesaver slv in-line monitors
Hide thumbs Also See for 9820:
Table of Contents

Advertisement

Clearing Performance Statistics

9820-A2-GB20-20
Performance statistics counters can be reset to the baseline when using a directly
connected asynchronous terminal and your security Access Level is Level-1. This
feature is useful when troubleshooting problems.
Statistic counters are not actually cleared using this feature. True statistic counts
are always maintained so SLAs can be verified, and they can be viewed from an
SNMP NMS. However, since statistics can be cleared locally, the statistics viewed
via the menu-driven user interface may be different from those viewed from the
NMS.
Procedure
To clear all statistics:
Performance Statistics
Procedure
To clear specific sets of statistics:
Use the C l rSLV&DLCIStats function key to reset the SLV and DLCI
performance statistic counters for the currently displayed DLCI from one of
the following screens:
Performance Statistics
Performance Statistics
Use the C l rLinkStats function key to reset the frame relay link performance
statistics.
Performance Statistics
Use the C l rStats function key to reset the Ethernet performance statistics.
Performance Statistics
June 2000
Clear All Statistics
Service Level Verification
DLCI
Frame Relay
Ethernet
Monitoring
6-29

Advertisement

Table of Contents
loading

This manual is also suitable for:

9820-2m9820-8m9820-45m

Table of Contents