Troubleshooting
Network or Port (Internal) PVC Loopback
Send Pattern
8-18
The PVC Loopback loops frames back to the selected interface on a per-PVC
basis. This test logically (not physically) loops back frames received from another
FrameSaver device through the selected frame relay PVC to the same device.
Main Menu
Test
Network PVC Loopback
DTE
Main Menu
Test
Port PVC Loopback
DTE
PVC # x
PVC # x
This test sends frames filled with a hexadecimal 55 test pattern and sequence
number over the selected interface on a per-DLCI basis.
To send a pattern test on a link:
Main Menu
Test
Send Pattern
If the selected
DLCI is configured as . . . Then . . .
Standard
Multiplexed
If the CIR is zero, the pattern will be sent at a rate of 1000 bps.
June 2000
Network PVC Tests
PVC Loopback
PVC # x
Network
PVC # x
98-16186
Data Port PVC Tests
PVC Loopback
Network
98-16187
[Network PVC Tests/Data Port PVC Tests]
(Disruptive) appears
after Test
(Non-Disruptive)
appears after Test
And the default
Rate (kbps) setting is . . .
100% of CIR
10% of CIR
9820-A2-GB20-20