Creating a Login

9820-A2-GB20-20
See
Configuring SNMP NMS Security Options
Options, for more information about SNMP NMS Security configuration options.
A login is required if security is enabled. (Security is enabled by the configuration
options Login Required for the communication port, and Telnet Login Required or
FTP Login Required for a Telnet or FTP Session.)
Up to six login ID/password combinations can be created using ASCII text, and
each login must have a specified access level. Logins must be unique and they
are case-sensitive.
Procedure
To create a login record:
1. Select Administer Logins.
Main Menu
Control
2. Select New, and set the following configuration options, as appropriate.
In the field . . .
Login ID
Password
Re-enter password
Access Level
NOTE:
See
Resetting the Unit and Restoring Communication
Troubleshooting , should you be locked out inadvertently.
3. Save your changes.
When Save is complete, the cursor is repositioned at the Login ID field, ready
for another entry.
June 2000
in Chapter 4, Configuration
Administer Logins
Enter the . . .
ID of 1 to 10 characters.
Password from 1 to 10 characters.
Password again to verify that you entered the
correct password into the device.
Access level: 1, 2, or 3.
Level-1 – User can add, change, and
display configuration options, save, and
perform device testing.
Level-2 – User can monitor and perform
diagnostics, display status and
configuration option information.
Level-3 – User can only monitor and
display status and configuration screens.
CAUTION: Make sure at least one login is set
up for Level-1 access or you may be
inadvertently locked out.
Security and Logins
in Chapter 8,
5-11