Figure 35 Ascii Drop Port Assignment Switches; Table 8 J892 Ascii Port Address Settings - Black & Decker d984 Installation Manual

Table of Contents

Advertisement

TOP OF MODULE
Switch 1 sets the RS232 handshaking for the bottom port
1 = Data Terminal Ready
0 = XONiXOFF
Switch 2 sets the FE232 handshaking for the top port
1 = Data Terminal Ready
0 = XONIXOFF
Switches 3 - 6 set device/port address per Table 8
Switch 7 is for Continuous Confidence Test Mode
1 = Local Diagnostic (takes unit Off-line)
0 = On-Line (Normal setting)
Switch 8 is not used, always set in the 0 position
Figure 35 ASCII Drop Port Assignment
Switches
Table 8
J892 ASCII Port Address Settings
ADDRESS
12
0
0
0
0
3,4
1
0
0
0
5,6
0
1
0
0
728
1
1
0
0
9,lO
0
0
1
0
11,12
1
0
1
0
13,14
0
1
1
0
15,16
1
1
1
0
17,18
0
0
0
1
19,20
1
0
0
1
21,22
0
1
0
I
23,24
1
1
0
1
25,26
0
0
1
1
27,28
1
0
1
1
29,30
0
1
1
1
31,32
1
1
1
1
LSB
MSB
SW3
4
5
6
1
2
4
8 = binary weighted value
GM4984-EDK