Figure 32 I/O Map Data - Black & Decker d984 Installation Manual

Table of Contents

Advertisement

Reselect
the program and go to configuration screen. Proceed to add the I/O
Mapping information for these two modules to the configuration data you already
established by:
Step
11
Enter the number of I/O modules as the value 2, from the
"Overview" menu.
Step
12
Go to the "IO/Map" menu function and define the presence
of the two modules. Figure 32 is an example of what the
data looks like.
Utility
DelDrop
HoldTme
ASCPort
GetDrop
Fl-F2-F3-F4-F5++
-
F7
Lev
B-F%OFF--%--
I/D
MAR
800
SERIES
I/O
Drop
:
1
of1
Rack
1
Drop
Hold
Up Time
: 3
(xl@Etns)
ASCII
Port
:
0
Number
Inputs
:
16
Number
Outputs
:
16
Maduls
Reference
Nunbers
Data
Module
Slot
TYPO
Input
output
type
Description
101
984
PLC-485E
102
8805
10001
-10016
l&IN
BE05
103
BEeI
00001 -00016
l&OUT
B804
104
88
105
8.3
106
88
107
BB
108
BB
109
88
110
08
Figure 32 I/O Map Data
Step 13
Return to the main menu and select the Transfer "File to
PLC" menu and at the "Start" prompt, respond with " Y" and
watch the RUN LED go on.
Step
14
You have now repeated the earlier steps (step 10) to
download the configuration but this time the I/O map data is
downloaded with it.