Power Reduction/LED

Using LED Power Reduction page to reduce LED intensity during specificed hour(s), the maximum setting range is 24
hours.
LOCATION:Configuration>System>LED
Parameters:
Items
LED Intensity Timers
Time
Intensity
Maintenance
On time at link change
On at errors
WEB Interface:
Configuration/Power Reduction/LED
A.
Click
B. Set LED intensity for corresponding hours, then click Add button to attach list
C. Set the duration of LED full power when a link change occurs
D. Set the duration of LED full power when a link error occurs
E.
Click Save to apply the setting or Reset to restore the previous setting

Power Reduction/EEE

EEE is a power saving option that reduces that power usage when there is low or no traffic utilization. Using this page to
set EEE and urgent Queues.
LOCATION:Configuration>Power Reduction>EEE
Parameters:
Items
Enable
EEE Urgent Queue
Description
Time at which LED intensity is set
LED Intensity (10 levels increase by 10%, 0%=LED off, 100%=LED full power)
LED set full powr for a period of time(second) when a link change occurs.
LED set full power when a link error occurs.
Description
Enable/Disable EEE for each ports
Queues set will activate transmission of frames as soon as any data is available, Otherwise
the queue will postpone the transmission until 3000 bytes are read to be transmitted.
Note: Ports that are not EEE-capable are grayed out and thus impossible to enable EEE for.