Component Teardown
Eyebrow Trim Removal
NOTE: The eyebrow trim, switches and humidity sensor
mounted under the eyebrow trim are only used on models
equipped with a dispenser.
The eyebrow trim extends across the front top of the unit
cabinet and covers the door switches, wire harness and

humidity sensor.

To remove the eyebrow trim:
1. Remove upper hinge covers.
2. Extract the screws securing the eyebrow trim to the
unit frame.
3. Turn the eyebrow trim over to access the wire
harness connections to the door switches and
humidity sensor. Disconnect from the wire harness
at the connections from under the hinge covers.
(See Figure 6-30)
Fresh Food and Freezer Light Switch Removal
The food compartment light switches (one for each door)
are installed in the eyebrow trim across the top of the
cabinet.
To remove the switch:
1. Disconnect power from unit.
2. Extract the screws securing the eye brow trim in
position, then lift it up and expose the underside.
(See Figure 6-31)
3. Remove the switch from the eyebrow trim by
pressing in on the retaining latch and push through
the eyebrow trim. Reinstall in reverse order.
Humidity Sensor Removal
The humidity sensor is used to control the heater in
the food door mullion strip and is located in the top trim
across the top front of them cabinet between the hinge
covers. The sensor will turn on the heater when the
humidity in the room is over 50% and turn the heater
back off when the humidity drops below 50%.
To replace the sensor:
1. Disconnect power from unit.
2. Remove the screws securing the eyebrow to the
cabinet exterior between the top hinge covers.
3. Tip the cover forward and lift it free of the cabinet.
4. Disconnect the humidity sensor from the wire
harness. (See Figure 6-32)
5. Push the retaining latches away from the humidity
sensor and pull from bracket.
6. Resemble in reverse order.
Screws
Retaining
Latch
Retaining Latches
NOTE: The humidity sensor is mounted on the control
board for the non-dispensing models. Failure of the
humidity sensor for those models requires replacement of
the control board.