Voltage Readings At Green Coil Of Secondary Valve - Electrolux 5995502399 Service Manual

French door bottom freezer refrigerator dispenser and non-dispenser models
Table of Contents

Advertisement

Water System

Voltage Readings At Green Coil Of Secondary Valve

When Ice Maker is Filling
Voltage at Outlet
Voltage at Coil
120VAC
100±10% VAC
100VAC
85±10% VAC
100-120VAC
20-76 VAC
Voltage Readings At Yellow Coil Of Secondary Valve
When Filling A Glass With Water
Voltage at Outlet
Voltage at Coil
120VAC
119±10% VAC
100VAC
99±10% VAC
100-120VAC
0-80 VAC
Voltage Readings At Coil Of Primary Valve
When Ice Maker is Filling
Voltage at Outlet
Voltage at Coil
120VAC
56±10% VAC
100VAC
48±10% VAC
100-120VAC
10-43 VAC
100-120VAC
0 VAC
The Service Technician must remember that when testing the current flowing to the Primary Valve Coil
through the Diode, you are getting 30 cycle current instead of 60 cycle current. Therefore, the volt meter
will read about 1/2 the voltage that is going to the coil. The change in cycle of current does not effect the
efficiency of an electromagnetic coil.
Condition
Normal
Normal at 105VAC (Will require use of 50 Watt coil)
Bad connection, Fill Switch, or Heater in Ice Maker
Condition
Normal
Normal
Bad connection or bad Fill Switch
Condition
Normal
Normal at 105VAC (Will require use of 50 Watt coil)
Bad connection, Fill Switch, or Heater in Ice Maker
Open Diode (If current is normal at secondary coil)
5-6