Electrolux 5995502399 Service Manual page 12

French door bottom freezer refrigerator dispenser and non-dispenser models
Table of Contents

Advertisement

Basic Information
Models With Freezer Compartment Ice Maker And Without
Dispenser
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
Variable Speed Compressor
Operating Time
Freezer Temperature
Refrigerator Temperature
Low Side Pressure
(cut-in)
Low Side Pressure
(cut-out)
High Side Pressure
Wattage
Amps (running)
Base Voltage
Cabinet Size
23' SD, 28' SD, 23' CD
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
(Energy Star, some models)
Electrical
Thermostat
Heater Voltage
Wire Number
CONTROL SETTING
65°F (18°C) Ambient
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cut-in
25° F
(-4° C)
CONDENSER FAN MOTOR
Watts
3.1
ICE MAKER SPECIFICATIONS
115 vac (127 vac max)
Opens at 48° F (9° C), Closes at 15° F (-9° C)
85 vac
ICE MAKER CONNECTOR PLUG CONNECTIONS
1
2
3
4
32 to 40%
-6° to 6° F
-21° to -14° C
33° to 46° F
0.5° to 8° C
5 to 12 psi
34 to 83 kPa
-2 to 2 psi
-14 to 14 kPa
85 to 95 psi
586 to 655 kPa
40 to 55
.5 to 1.1
Thermostat
Cut-out
47° F
(8° C)
RPM
1100 CW
Opposite Shaft
Wire Color
Green/Yellow
Yellow
Black
Light Blue
1-10
90°F (32°C) Ambient
100%
-6° to 6° F
-21° to -14° C
33° to 46° F
0.5° to 8° C
N/A
-2 to 2 psi
-14 to 14 kPa
120 to 135 psi
827 to 931 kPa
60 to 70
.7 to .9
Heater
Watts
Ohms
500
26
Amps
0.03 Running
Connects to:
Ground
Water Valve
Line
Neutral

Hide quick links: