Testing The Compressor - Electrolux 5995502399 Service Manual

French door bottom freezer refrigerator dispenser and non-dispenser models
Table of Contents

Advertisement

Electronic Control
3. If the voltage checks good, remove the inverter
from the compressor by removing one screw at the
bottom of the inverter that goes through the bracket
welded to the compressor. (See Figure 3-16) Pull
the inverter away from compressor. Use a small
flat-bladed screwdriver to remove the plug from the
compressor terminals. Using an ohmmeter, check
the resistance between the compressor terminals
(See testing the compressor). If the compressor
checks good, replace the inverter.
Inverter
Mounting Screw
Figure 3-16
Yes
Are you receiving
Compressor
the proper signal
not running
.
form the lower
Controls set
control board
correctly
Replace main
control board
115 V
Yes
Is there 120
VAC to the
inverter board
No
No
Check wiring
and inverter
board
connections

Testing the Compressor

The compressor has a 3 phase, 4 pole brushless DC
motor. To test the compressor using your Ohmmeter,
check the resistance between the terminals. Check
should read 10 ohm +/- 10 % when using Figure 3-17 to
test.
2
Test
1 to 2
Motor
3 phase
4 poles
Brushless
Yes
Yes
Check for
10 Ohms between
each terminal
on compressor
No
Replace
compressor
and inverter
board
Figure 3-19
3-12
Test
2 to 3
3
Test
3 to 1
1
Figure 3-17
Lubrication
Modified
System
For Lower
Speeds
Power input
Electronic
Replaces
Starting Device
Figure 3-18
Yes
Check wiring
connections
Replace
between
inverter board
compressor and
inverter board
No
Repair
connections
Control
and OP

Hide quick links: