34. WARNING AND ERROR MESSAGES
New password Diff.
Passwords input when setting a new password do not match.
Input the same password twice.
No data
When searching for or reading in coordinate data or searching for code data,
the search stopped either because the item in question does not exist or the
data volume is large.
No file
There is no file for loading known point data or displaying data on the currently
selected USB memory device.
No solution
The calculation of the instrument station coordinates during resection does
not converge.
Assess the results and if necessary, perform the observation again.
Intersect point could not be calculated. Either necessary data items were not
input or the Intersect point does not exist.
North/East is null, Read error
The Northing or Easting field of the given coordinate is null.
Input the coordinate.
Out of range
The tilt of the instrument exceeds the tilt angle compensation range during
measurement.
Level the instrument again.
"7.2 Levelling"
A direction which does not cross with the base plane during plane offset
measurement.