34. WARNING AND ERROR MESSAGES
Signal off
Measuring conditions are poor, and there is not any reflective light for
measuring distances.
Resight the target. When using reflective prisms, effectiveness will be
improved by increasing the number of prisms used.
Station coord is Null
Cannot calculate. Station point coordinate is set to "Null".
Input the coordinate.
Temp Range OUT
CX is outside useable temperature range and accurate measurement cannot
be performed. Repeat measurement within the appropriate temperature
range. If the CX is used under direct sunlight, use an umbrella to protect it
against the heat of the sun.
Time out (during measurement)
Measuring conditions are poor, and due to the insufficient amount of reflective
light, measuring could not be carried out within the time specified.
Resight the target. When using reflective prisms, effectiveness will be
improved by increasing the number of prisms used.
Too short
Input password has fewer than 3 characters. Password must have 3 or more
characters and 8 or fewer characters.
USB error
An error has occurred in loading or saving data to USB memory device.
USB full !
There is no more room to enter data on USB memory device.
USB not found
USB memory device was removed during USB mode operation.
* * * * * * * *
The calculated result is too large to be displayed on the screen in its totality.