7. SETTING UP THE INSTRUMENT
4. Adjust the levelling foot screws to
center the survey point in the
optical plummet reticle.
5. Continue to the levelling
procedure.
"7.2 Levelling"
PROCEDURE Centering with the laser plummet (
1. Set up the tripod and affix the
instrument on the tripod head.
"PROCEDURE Centering with
the optical plummet eyepiece"
steps 1 and 2
2. Press {ON} to power on
"9. POWER ON/OFF"
• The circular level is displayed on
the screen.
3. Press [L-ON].
The laser plummet beam will be
emitted from the bottom of the
instrument.
4. Use {}/{} to adjust the
brightness of the laser.
5. Adjust the levelling foot screws to
align the laser beam with the
center the survey point.