Sokkia CX-101 Service Manual page 77

Compact x-ellence station cx series
Hide thumbs Also See for CX-101:
Table of Contents

Advertisement

2. Press [BS NEZ] after entering the
instrument station data to enter a
backsight point coordinate.
• When you wish to read in the
registered coordinate data,
press [LOAD].
""13.1 Entering Instrument
Station Data and Azimuth
Angle" PROCEDURE
Reading in Registered
Coordinate Data"
3. Input the backsight station
coordinates and press [OK].
4. The backsight angle is displayed
in "Azmth". Press [YES], set an
azimuth angle and return to
<Coord>.
• Pressing [NO] returns to the
step 2 screen.
• Pressing [MEAS] after
collimating the backsight point
initiates measurement. When
measuring is completed, the
backsight distance check screen
is displayed. The difference
between the calculated value
and the measured height
distance value is displayed.
After confirming, press [OK].
• Press [HT] to set instrument and
target height.
• Press [REC] to store check data
in the current JOB
13. SETTING INSTRUMENT STATION
Backsight
NBS:
EBS:
ZBS:
LOAD
Backsight
Take BS
ZA
89
HA-R
117
Azmth
REC
MEAS
BS Hdist check
calc HD
obs HD
dHD
REC
HT
100.000
100.000
<Null>
OK
59
55
32
20
45 00 00
NO
YES
15.000m
13.000m
2.000m
OK
67

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cx-102Cx-103Cx-105Cx-107

Table of Contents