6. Press [L-OFF] to turn the laser
plummet off.
Alternatively, press {ESC} to return
to the previous screen. The laser
plummet will switch off
automatically.
7. Continue to the levelling
procedure.

"7.2 Levelling"

• Visibility of the laser spot may be affected when operating in direct sunlight. In
this event, provide shade for the survey point.
7.2
Levelling
PROCEDURE
1. Perform the centering procedure.
"7.1 Centering"
2. Center the bubble in the circular
level by either shortening the
tripod leg closest to the offcenter
direction of the bubble or by
lengthening the tripod leg farthest
from the offcenter direction of the
bubble. Adjust one more tripod leg
to center the bubble.
Turn the levelling foot screws while
checking the circular level until the
bubble is centered in the center
circle.
7. SETTING UP THE INSTRUMENT
Tripod legs
adjustment
31