Configuration Procedure; Monitor Link Configuration Example; Displaying And Maintaining Monitor Link - H3C S5120-EI Series Operation Manual

Hide thumbs Also See for S5120-EI Series:
Table of Contents

Advertisement

Configuration procedure

<Sysname> system-view
[Sysname] monitor-link group 1
[Sysname-mtlk-group1] port gigabitethernet 1/0/1 uplink
[Sysname-mtlk-group1] port gigabitethernet 1/0/2 downlink

Displaying and Maintaining Monitor Link

To do...
Display monitor link
group information

Monitor Link Configuration Example

Network requirements
As shown in
Figure
Device C is dually uplinked to Device A through a smart link group.
It is required that when GigabitEthernet 1/0/1 or GigabitEthernet 1/0/2 of Device A fails, Device C
can sense the link failure and perform link switchover in the smart link group.
For detailed information about smart link, refer to Smart Link Configuration in the Access Volume.
Figure 1-1 Network diagram for smart link in combination with monitor link configuration
GE1/0/1
GE1/0/1
GE1/0/2
Device B
GE1/0/1
Configuration procedure
1)
Configuration on Device C
# Create smart link group 1.
<DeviceC> system-view
Use the command...
display monitor-link group
{ group-id | all }
1-1:
Device A
GE1/0/2
GE1/0/1
GE1/0/2
Device D
GE1/0/2
Device C
Available in any view