After completing the above configurations, you can use the following command to view the
configuration information of the RADIUS scheme named radsun:
<Switch> display radius scheme radsun
SchemeName
: radsun
Index : 1
Primary Auth IP
: 192.168.1.2
Primary Acct IP
: 192.168.1.3
Second
Auth IP
: 192.168.1.3
Second
Acct IP
: 192.168.1.2
Auth Server Encryption Key : name
Acct Server Encryption Key : money
Accounting-On packet disable, send times : 5 , interval : 3s
Interval for timeout(second)
Retransmission times for timeout
Interval for realtime accounting(minute)
Retransmission times of realtime-accounting packet
Retransmission times of stop-accounting packet
Quiet-interval(min)
Username format
Data flow unit
Packet unit
Use the following command to view the configuration information of the ISP domain named sun:
<Switch> display domain sun
Domain = sun
State = Active
Access-limit = 30
Accounting method = Required
Default authentication scheme
Default authorization scheme
Default accounting scheme
Domain User Template:
Idle-cut = Disabled
Self-service = Disabled
Use the following command to view the port security configuration information:
<Switch> display port-security interface gigabitethernet 1/0/1
Equipment port-security is enabled
Trap is disabled
Disableport Timeout: 20s
OUI value:
Index is 1,
OUI value is 123401
Index is 2,
OUI value is 123402
Index is 3,
OUI value is 123403
Index is 4,
OUI value is 123404
Index is 5,
OUI value is 123405
GigabitEthernet1/0/1 is link-up
Port mode is userLoginWithOUI
Type : standard
Port : 1812
State : active
Port : 1813
State : active
Port : 1812
State : active
Port :1813
State : active
: 5
: 5
: 15
: 5
: 500
: 5
: without-domain
: Byte
: one
: radius=radsun
: radius=radsun
: radius=radsun
1-15