9-2 Error Messages
When the display reads "cAution"
Error code
Meaning
1-01
Muting occurred because
off-tape MAIN ID was
invalid.
Cannot play data storage
tapes or tapes with a 32
kHz sampling frequency.
1-02
Invalid off-tape SUB ID.
1-10
Recording interrupted
because servo-unlock
occurred.
1-11
Error occured in input
digital audio signal during
recording.
1-12
Recording interrupted
because insert recording
does not allow insertion of
audio/sub-code data into
blank parts of a tape.
1-20
Tape reached beginning or
end during locating.
1-21
Locating interrupted
because program numbers
are not continuous.
Renumber program
numbers.
1-22
Locating interrupted
because the time code is
not continuous or time
code is not recorded at the
desired locate point.
1-30
Preview, auto edit, or spot
erase interrupted because
time code is not continuous
or not properly recorded.
1-40
The oscillation of the clock
stopped. Check the date
and time setting.
1-50
The setting of DIP switch
on SSP board is abnormal.
2-02
The hour meter (the
accumulated time of head
drum) reached the time
limit for checking. Consult
qualified Sony personnel.
2-50
The setting of DIP switch
on SV board is abnormal.
*The display disappear when you press the STOP key.
9-4
Chapter 9 Warning Indicators and Error Messages
9-2-3 Displaying the Error
Correction Code List
Error level
1
This unit memorized up to 500 points at which muting,
interpolation or correction occurred during playback or
recording in monitor recording mode. You can display
the error contents and the time codes of those points.
1
1
Turn the search dial while holding down the
2
MENU key and set the display to "Ecc".
2
2
2
Turn the search dial while holding down the
DATA key.
The serial No. is changed.
2
Every time you press the MENU key, the serial
No. changes in the order of 1 - 100 - 200 - 300 -
2
400 - 500 - ....
*
2
2
To listen to the sound around an error point
2*
Press the LOCATE key.
This unit positions the tape to a point 5 seconds prior
to the point of the displayed time code, then starts
3
playback.
2*
To clear the error list
Press the RESET key while holding down the DATA
key.
While the "Ecc" is not displayed, you can clear the list
3
by pressing the EJECT key and removing the cassette.
To output the error list at the RS-232C
connector
Press the SET key while holding down the DATA key.
This unit outputs the error list (text data) at the RS-
232C connector on the connector panel (rear).
Notes
When the number of error points exceeds 500, the
error points are overwritten from point 1.
***
Number (1 to 500)
***
***
No. of error block of B-ch
(- azimuth)
No. of error block of A-ch
(+ azimuth)
Error
c: Error correction over a specific
value
i: Compensation
E: Mute