Whole display
This section explains all the information that may
appear in the display.
Tape time display area
1
TIME CODE
EBU SMPTE
ABS TIME
COUNTER
CH-1
CH-2
Level meters
1 Time code indication
TIME CODE: When a time code is recorded or
reproduced, this indicator lights along with displaying
"SMPTE" or "EBU" depending on the type of time
code used.
See section 7-3 "Dial Menu Operations" (page 7-5) to
change the setting of the time code in dial menu.
2 Start ID write/erase indication
START ID WRITE: This indication appears when a
Start ID is written to a tape.
START ID ERASE: This indication appears when a
Start ID is erased from a tape.
AUTO REC: This indication appears when the
automatic Start-ID writing mode is set.
See section 7-3 "Dial Menu Operations" (page 7-5).
When a Start ID is read from a tape during playback,
"START-ID" appears.
3
2
START ID
VIDEO
WRITE ERASE
2529.9730
AUTO REC
SYNC PB
H
H
H
-
-60
-50
-42
-34
-28
-22
-18
4
EXT SYNC
EXT TIME CODE
D-IWORD
GEN TIME CODE
WIDE
EXT
U-BIT
LOCATE POINT
CHASE OFFSET
NDF
DF
dB
H
HF
MB
-14
-10
-8
-6
-4
-2
0
OVER
8
Sampling frequency indicator
3 Sync signal indication
VIDEO: When the unit goes into the mode for video
synchronization, this indication appears along
with the frequency display "25", "29.97", or "30".
SYNC PB: This indication appears when playback is
carried out under the following conditions:
1) the time code format is other than Film.
2) A video sync signal is input to the REF VIDEO
INPUT connector on the connector panel.
3) the setup menu "SYNC PB" is set to
"ENABLE" to lock the off-tape time code and
the input video sync signal in phase.
See section 7-3 "Dial Menu Operations" (page 7-5).
EXT SYNC: When the unit goes into the mode for
external synchronization (when the SYNC signal
selector is set to EXT), this indication appears
along with the display "D-I" (in the AES/EBU
format) or "WORD" (for a word sync signal)
depending on the type of synchronizing signal
used.
Chapter 2 Location and Function of Parts and Controls
5
Input/set data
display area
GEN SET
U-BIT TIME
ELAPSE
GEN U-BIT
VARI SPEED
dB
S
F%
Chase mode
REC CHASE
FREE RUN
indicator
EMPH
FS 44 . 148
7